Programming Reference / Motion / Brake Resistor
The Brake Resistor block allows you to select how you want motor back EMF regeneration to be handled based upon your application.
Item | Description |
---|---|
A | Select the Slot for the particular InoDrive you want to define braking resistor options |
B | From the drop down, select the desired braking resistor function |
Brake Resistor Options
Item | Description |
---|---|
Shared | The InoDrive monitors the DC voltage bus and automatically adjusts its internal braking resistor to minimize voltage regeneration onto the DC bus (Default). |
Local Only | The InoDrive monitors only its local motor’s behavior and automatically adjusts its internal braking resistor so there is no voltage regeneration onto the DC bus. |
Combined | The InoDrive monitors both the DC voltage bus and its local motor’s behavior and automatically adjusts its internal braking resistor to minimize voltage regeneration onto the DC bus |
Disabled | The InoDrive provides no automatic control of its internal braking resistor and any back EMF produced by its local motor will be regenerated onto the DC bus |